本論文提出差動波包偵測法消除兩正交極化狀態中共同路徑的背景雜訊,以改善傳統時域極化光學同調斷層攝影術(TD-PS-OCT)延遲相位的量測靈敏度。並搭配快速掃描延遲線(RSOD)調變技術,快速取得一張截面式(cross-section)的斷層影像,並且呈現人類血管的量測結果,其代表微弱雙折射特性的介質。論文最後對極化光學同調斷層顯微鏡(PS-OCM)的研發做初步的討論。
1. D. Huang, E. Swanson, C. Lin, J. Schuman, W. Stinson, W. Chang, M. Hee, T. Flotte, K. Gregory, and C. Puliafito, "Optical coherence tomography," Science 254, 1178-1181 (1991).
2. J. Fujimoto, M. Brezinski, G. Tearney, S. Boppart, B. Bouma, M. Hee, J. Southern, and E. Swanson, "Optical biopsy and imaging using optical coherence tomography," Nature Medicine 1, 970-972 (1995).
3. M. Hee, D. Huang, E. Swanson, and J. Fujimoto, "Polarization-sensitive low-coherence reflectometer for birefringence characterization and ranging," Journal of the Optical Society of America B 9, 903-908 (1992).
4. K. Schoenenberger, B. Colston, D. Maitland, L. Da Silva, and M. Everett, "Mapping of birefringence and thermal damage in tissue by use of polarization-sensitive optical coherence tomography," Applied optics 37, 6026-6035 (1998).
5. M. Ducros, J. Marsack, H. Rylander III, S. Thomsen, and T. Milner, "Primate retina imaging with polarization-sensitive optical coherence tomography," Journal of The Optical Society of America A 18, 2945-2956 (2001).
6. N. Ugryumova, D. Attenburrow, C. Winlove, and S. Matcher, "The collagen structure of equine articular cartilage, characterized using polarization-sensitive optical coherence tomography," JOURNAL OF PHYSICS-LONDON-D APPLIED PHYSICS 38, 2612 (2005).
7. W. Kuo, N. Chou, C. Chou, C. Lai, H. Huang, S. Wang, and J. Shyu, "Polarization-sensitive optical coherence tomography for imaging human atherosclerosis," Applied optics 46, 2520-2527 (2007).
8. J. De Boer, T. Milner, M. van Gemert, and J. Nelson, "Two-dimensional birefringence imaging in biological tissue by polarization-sensitive optical coherence tomography," Optics letters 22, 934-936 (1997).
9. E. G tzinger, M. Pircher, M. Sticker, A. Fercher, and C. Hitzenberger, "Measurement and imaging of birefringent properties of the human cornea with phase-resolved, polarization-sensitive optical coherence tomography," Journal of Biomedical Optics 9, 94-102 (2004).
10. C. Hitzenberger, E. Goetzinger, M. Sticker, M. Pircher, and A. Fercher, "Measurement and imaging of birefringence and optic axis orientation by phase resolved polarization sensitive optical coherence tomography," Optics Express 9, 780-790 (2001).
11. D. Dav , T. Akkin, and T. Milner, "Polarization-maintaining fiber-based optical low-coherence reflectometer for characterization and ranging of birefringence," Optics letters 28, 1775-1777 (2003).
12. E. G tzinger, M. Pircher, and C. Hitzenberger, "High speed spectral domain polarization sensitive optical coherence tomography of the human retina," Optics Express 13, 10217-10229 (2005).
13. R. Leitgeb, C. Hitzenberger, and A. Fercher, "Performance of fourier domain vs. time domain optical coherence tomography," Optics Express 11, 889-894 (2003).
14. J. De Boer, B. Cense, B. Park, M. Pierce, G. Tearney, and B. Bouma, "Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography," Optics letters 28, 2067-2069 (2003).
15. J. De Boer, T. Milner, and J. Nelson, "Determination of the depth-resolved Stokes parameters of light backscattered from turbid media by use of polarization-sensitive optical coherence tomography," Optics letters 24, 300-302 (1999).
16. C. Saxer, J. de Boer, B. Park, Y. Zhao, Z. Chen, and J. Nelson, "High-speed fiber based polarization-sensitive optical coherence tomography of in vivo human skin," Optics letters 25, 1355-1357 (2000).
17. J. Zhang, W. Jung, J. Nelson, and Z. Chen, "Full range polarization-sensitive Fourier domain optical coherence tomography," Optics Express 12, 6033-6039 (2004).
18. B. Cense, T. Chen, M. Mujat, C. Joo, T. Akkin, B. Park, M. Pierce, A. Yun, B. Bouma, and G. Tearney, "Spectral domain polarization-sensitive optical coherence tomography at 850 nm," (2005), pp. 159-162.
19. G. Yao, and L. Wang, "Two-dimensional depth-resolved Mueller matrix characterization of biological tissue by optical coherence tomography," Optics letters 24, 537-539 (1999).
20. Y. Yasuno, S. Makita, Y. Sutoh, M. Itoh, and T. Yatagai, "Birefringence imaging of human skin by polarization-sensitive spectral interferometric optical coherence tomography," Optics letters 27, 1803-1805 (2002).
21. S. Jiao, and L. Wang, "Two-dimensional depth-resolved Mueller matrix of biological tissue measured with double-beam polarization-sensitive optical coherence tomography," Optics letters 27, 101-103 (2002).
22. S. Jiao, W. Yu, G. Stoica, and L. Wang, "Optical-fiber-based Mueller optical coherence tomography," Optics letters 28, 1206-1208 (2003).
23. Y. Yasuno, S. Makita, T. Endo, M. Itoh, T. Yatagai, M. Takahashi, C. Katada, and M. Mutoh, "Polarization-sensitive complex Fourier domain optical coherence tomography for Jones matrix imaging of biological samples," Applied Physics Letters 85, 3023-3025 (2004).
24. B. Park, M. Pierce, B. Cense, S. Yun, M. Mujat, G. Tearney, B. Bouma, and J. de Boer, "Real-time fiber-based multi-functional spectral-domain optical coherence tomography at 1.3 microm," Optics Express 13, 3931-3944 (2005).
25. S. Jiao, M. Todorovic, G. Stoica, and L. Wang, "Fiber-based polarization-sensitive Mueller matrix optical coherence tomography with continuous source polarization modulation," Applied optics 44, 5463-5467 (2005).
26. M. Yamanari, S. Makita, V. Madjarova, T. Yatagai, and Y. Yasuno, "Fiber-based polarization-sensitive Fourier domain optical coherence tomography using B-scan-oriented polarization modulation method," Optics Express 14, 6502-6515 (2006).
27. B. Bouma, and G. Tearney, Handbook of Optical Coherence Tomography (Informa Healthcare, 2002).
28. R. Youngquist, S. Carr, and D. Davies, "Optical coherence-domain reflectometry: a new optical evaluation technique," Optics letters 12, 158-160 (1987).
29. W. Drexler, U. Morgner, F. K rtner, C. Pitris, S. Boppart, X. Li, E. Ippen, and J. Fujimoto, "In vivo ultrahigh-resolution optical coherence tomography," Optics letters 24, 1221-1223 (1999).
30. J. Izatt, M. Hee, G. Owen, E. Swanson, and J. Fujimoto, "Optical coherence microscopy in scattering media," Optics letters 19, 590-592 (1994).
31. K. Wiesauer, M. Pircher, E. G tzinger, S. Bauer, R. Engelke, G. Ahrens, G. Gr tzner, C. Hitzenberger, and D. Stifter, "En-face scanning optical coherence tomography with ultra-high resolution for material investigation," Optics Express 13, 1015-1024 (2005).
32. M. Pircher, E. Goetzinger, R. Leitgeb, and C. Hitzenberger, "Transversal phase resolved polarization sensitive optical coherence tomography," Physics in Medicine and Biology 49, 1257-1263 (2004).
33. C. Hitzenberger, P. Trost, P. Lo, and Q. Zhou, "Three-dimensional imaging of the human retina by high-speed optical coherence tomography," Optics Express 11, 2753-2761 (2003).
34. K. Zheng, B. Liu, C. Huang, and M. Brezinski, "Experimental confirmation of potential swept source optical coherence tomography performance limitations," Applied optics 47, 6151-6158 (2008).
35. M. Everett, K. Schoenenberger, J. Colston, BW, and L. Da Silva, "Birefringence characterization of biological tissue by use of optical coherence tomography," Optics letters 23, 228-230 (1998).
36. G. Tearney, B. Bouma, and J. Fujimoto, "High-speed phase-and group-delay scanning with a grating-based phase control delay line," Optics letters 22, 1811-1813 (1997).
37. R. Azzam, and N. Bashara, "Ellipsometry and Polarized Light 1North-Holland," Amsterdam 19892, 75.
38. N. Shibata, M. Tsubokawa, T. Nakashima, and S. Seikai, "Temporal coherence properties of a dispersively propagating beam in a fiber-optic interferometer," Journal of The Optical Society of America A 4, 494-497 (1987).
39. A. Podoleanu, M. Seeger, G. Dobre, D. Webb, D. Jackson, and F. Fitzke, "Transversal and longitudinal images from the retina of the living eye using low coherence reflectometry," Journal of Biomedical Optics 3, 12-20 (1998).
40. C. Hitzenberger, P. Trost, P. Lo, and Q. Zhou, "Three-dimensional imaging of the human retina by high-speed optical coherence tomography," Optics Express 11, 2753-2761 (2003).
41. E. Nash, "Ask the applications engineer—28, logarithmic amplifiers explained," Analog Dialogue 33, 1-5 (1999).
42. A. Arbel, J. Booz, K. Mhuller, and H. Neuhaub, "Development of a portable microdosimetric radiation protection monitor covering a dynamic range of 120 dB above noise," IEEE Transactions on Nuclear Science 31, 691-696 (1984).
43. J. Roth, J. Kozak, S. Yazdanfar, A. Rollins, and J. Izatt, "Simplified method for polarization-sensitive optical coherence tomography," Optics letters 26, 1069-1071 (2001).